  • NEC Requirements for Generators and Standby Power Systems
    Mike Holt Enterprises, Inc • www MikeHolt com • 888 NEC CODE (632 2633) 5 NEC Requirements for Generators and Standby Power Systems 445 18 Disconnecting Means Generators must have one or more disconnecting means that disconnects all power, except where: Figure 445–7 (1) The driving means for the generator can be readily shut down, and
  • Mike holt - Electrician Talk
    TheNEC also requires certain types of circuits in specific places in addition to the minimum requirements based on the VA per sq ft calculation A dwelling unit kitchen, dining room, breakfast room, pantry, or similar area must have at least two 20A, 120V small-appliance receptacle
  • Feeders and Branch Circuits in the same Conduit.
    Is there an NEC article that requires Branch circuits and feeders to be in different conduits? Specifically I'm wondering about two panel tubs that are nipple together and do I need a separate nipple for the feeders and for the branch circuits
  • Gas station wiring requirements | Electrician Talk
    NEC 2017 514 8 Underground Wiring ENHANCED CONTENT Fuel spilled in the vicinity of gasoline dispensers seeps into the ground and could migrate into underground electrical conduits
  • Understanding Table 220-55 - Electrician Talk
    The NEC does not define ranges, ovens or cooktops but based on manufacturers usage a range is a unit that has a cooktop and oven built together in one appliance An oven is just a single or double appliance for baking , roasting, etc A cooktop is just the burners without the oven
  • 80% rule? - Electrician Talk
    80% rule applies to continious loads such as motors, lighting or any load expected to be on 3 hours or more A breaker is rated for 100% of the noncontinious load which may include outlets or other small appliance
  • Inconsistent Confusing Conduit Fill Calculation.
    As I said, according to NEC tables 9-1 and 9-5 1 2" EMT is acceptable I don't believe this is acceptable in this case and I don't think a local inspector or any of my local electricians would think it is even if a logically correct argument can be made to show it is allowed under NEC This is exactly my point
  • Table 300. 5 interpretation - Electrician Talk
    For a given column of Table 300 5 ("minimum cover requirements") there is a potential overlap of the various rows The one that concerns me at present is Column 2 (IMC and RMC conduit) If it's buried in a trench below 2" of concrete or equivalent, but also goes under a parking area in a